logo
Send Message

MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.

 

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsVortex Flow Meter

SS316 Steam Vortex Flow Meter Low Flow Rate LCD Display Low Pressure Loss

SS316 Steam Vortex Flow Meter Low Flow Rate LCD Display Low Pressure Loss

  • SS316 Steam Vortex Flow Meter Low Flow Rate LCD Display Low Pressure Loss
SS316 Steam Vortex Flow Meter Low Flow Rate LCD Display Low Pressure Loss
Product Details:
Place of Origin: China
Model Number: LUGBML
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Price: Negotiation
Packaging Details: In Carton or Wooden Box
Delivery Time: 7-10 working days
Payment Terms: T/T
Supply Ability: 500pcs per month
Contact Now
Detailed Product Description
Product Name: Vortex Flow Meter Application: Oil,chemical Industry,metallurgy,heating Power,spinning,pape Rmaking ,etc
Accuracy: ±1.0% For Liquid, ±1.5% For Gas Body Material: 304 SS For Standard, 316 SS For Option
Power Supply: 24VDC/12VDC,3.6V Lithium Battery Protection Class: IP65
Highlight:

vortex gas flow meter

                           Insertion Type Vortex Flow Meter Temperature Pressure Compensation with Modbus RS485

 

1. Introduction

LUGBML is based on Von Karman’s Vortex Principle, which adopts piezoelectric crystal as testing components. It is a new kind of stress detecting vortex flow meter. It has the advantage of wide range ratio, high accuracy, low pressure loss, good medium generality, pulse output proportional to flow, convenient to connect with computer and etc. As the detector probe of sensor and the vortex generating body are installed separately, and the high temperature resistant piezoelectric crystal doesn’t contact with medium, so the instrument is of simple structure, good generality and high stability.

LUGBML series Vortex Flow Meter sensor can be used to detect and measure the flow of all kinds of gas, liquid and steam.

LUGBML series Vortex Flow Meter can be used to match with our company’s ML6000 series Velocity Flowmeter. It can also match with a computer and sensors of temperature, pressure, or density to compose high accuracy mass flow or heat flow detecting and measuring system.

 

2. Application

LUGBML series is suitable for oil,chemical industry,metallurgy,heating power,spinning,pape rmaking ,etc. Be use of control: over-heating vapor, saturation vapor, compressed air,ordinary air(oxygen, nitrogen, hydrogen, natural gas, coal gas ,etc),water and liquid (water, petrol ,alcohol, benzene ,etc.)

 

3. Specifications

1) Measuring medium: Steam,gas, liquid(Avoid of multiple- direction fluid)

2) Accuracy:Liquid:1.0% Gas:1.5%

3) Repeatability:Liquid 0.33% Gas:0.5%

4) Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s

5) Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)

6) Fluid temperature:-40℃~250℃(Common type);100℃~350℃(High-temperature type)

7) Body material:304 stainless steel(SS316 is optional)

8) Output signal:Pulse(three wires,low level≤1V;High level≧4V);4~20mA;RS485

9) Power supply:24VDC(12VDC),Lithium battery

10) Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD ); -5℃~60℃(with LCD)

11) Relative humidity:5~95%

12) Protection level:IP65

13) Electrical connection:M20*1.5

 

4. Design & Installation

It is very important to install the instrument, if not properly installed, it will affect the accuracy, service life and damage.

 

1. In order to avoid switch sets with strong power, high frequency and high power, the meter power supply should be kept away from these devices.

2. Avoid high temperature and radiation sources. If installation is required, take heat insulation ventilation measures.

3. In order to avoid high temperature and enchanted gas, ventilation measures should be taken if installation is required.

4. Vortex flowmeter should not be installed on the part of pipe shaking. If it must be installed on it, a clamping device and a vibration pad located in 2D should be added to enhance the shock resistance. It is better for the instrument to be installed indoors and outdoors, and pay attention to water proof. Pay special attention to the joints, make the cable lead u-shaped, so as to avoid water entering the amplifier body. Enough space should be saved at the installation place to facilitate the installation of the connection line and daily maintenance.

    

 

5. Configuration

                                           LUGBML Series Vortex Flow Meter Configuration
Model LUGBML
Sensor Installation D Clamp Type Sensor
F Flange Type Sensor
C Insertion Type Sensor
Medium L Liquid
G Gas
S Steam
Pipe Material 25 25mm
......  
300 300mm
Power Supply A Duplicate Supply(24VDC/12VDC+3.6V Lithium Battery)
B 3.6V Lithium Battery
C 24VDC/12VDC
Display D With Digital Display
P Without Digital Display
Output N None
P Pulse
A 4-20mA
R RS485
H Hart
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Sensor Material A 304 SS (Standard)
B 316 SS
O Others
Medium Temperature E 40~250℃
H 100~350℃
Rated Pressure 16 1.6MPa
25 2.5MPa
40 4.0MPa
O Others
Protection Class 0 IP65
Explosion Proof 0 None
EX Explosive Proof

 

Contact Details
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Contact Person: Ms. Nancy Zhao

Tel: 0086-21-57652429

Fax: 0086-21-57652430

Send your inquiry directly to us
Other Products